Module for Lemi B423E data
Lemi B423E always records channels in the following order
- E1, E2, E3, E4
The Lemi B423E binary files are constructed from a 1024 text header followed
by repeating records with the following definitions (PPS is short for
deviation from PPS and PLL is short for PLL accuracy):
SECOND_TIMESTAMP, SAMPLE_NUM [0-FS], E1, E2, E3, E4, PPS, PLL
These are interpreted to have byte types
L, H, l, l, l, l, h, h
The channels labels are not that useful for magnetotelluric projects. When
creating metadata it is best to map them to standard channels such as Ex or Ey
"""
from loguru import logger
from typing import List, Optional, Tuple
from pathlib import Path
import numpy as np
import pandas as pd
from resistics.time import TimeMetadata, TimeData
from resistics_readers.multifile import validate_consistency, validate_continuous
from resistics_readers.multifile import TimeMetadataMerge
from resistics_readers.lemi.b423 import TimeMetadataB423, TimeReaderB423
B423E_CHANS = ["E1", "E2", "E3", "E4"]
B423E_RECORD_BYTES = 26
B423E_HEADER_LENGTH = 1024
B423E_MULT = ["Ke1", "Ke2", "Ke3", "Ke4"]
B423E_ADD = ["Ae1", "Ae2", "Ae3", "Ae4"]
def _get_B423E_metadata_list(
dir_path: Path, fs: float, chans: Optional[List[str]] = None
) -> List[TimeMetadataB423]:
"""
Get list of TimeMetadataB423, one for each data file
Parameters
----------
dir_path : Path
The data path
fs : float
The sampling frequency, Hz
chans : Optional[List[str]]
The channels, by default None. Standard channels are E1, E2, E3 and E4,
but these have little meaning geophysically, so it is possible to
set different labels for the four channels
Returns
-------
List[TimeMetadataB423]
List of TimeMetadata
"""
from resistics_readers.lemi.b423 import _read_B423_headers
if chans is None:
chans = B423E_CHANS
data_paths = list(dir_path.glob("*.B423"))
metadata_list = []
for data_path in data_paths:
logger.debug(f"Reading data file {data_path}")
metadata_B423E = _read_B423_headers(
data_path,
fs,
data_byte_offset=B423E_HEADER_LENGTH,
record_bytes=B423E_RECORD_BYTES,
chans=chans,
)
metadata_list.append(metadata_B423E)
return metadata_list
def _merge_metadata(
metadata_list: List[TimeMetadataB423], dx: float = 1, dy: float = 1
) -> TimeMetadata:
"""Merge the metadata list into a TimeMetadata"""
metadata = TimeMetadata(**metadata_list[0].dict())
metadata.first_time = min([x.first_time for x in metadata_list])
metadata.last_time = max([x.last_time for x in metadata_list])
metadata.n_samples = np.sum([x.n_samples for x in metadata_list])
# channel headers
data_files = [x.data_file for x in metadata_list]
for chan in metadata.chans:
metadata.chans_metadata[chan].data_files = data_files
if chan == "Ex":
metadata.chans_metadata[chan].dipole_dist = dx
if chan == "Ey":
metadata.chans_metadata[chan].dipole_dist = dy
return metadata
[docs]class TimeReaderB423E(TimeReaderB423):
"""
Data reader for Lemi B423E data
There is no separate metadata file for Lemi B423E data detailing the
sampling frequency, the number of samples, the sensors etc.. Such a
metadata file is a pre-requisite for resistics. There are helper methods to
make one.
In situations where a Lemi B423E dataset is recorded in multiple files, it
is required that the recording is continuous.
Other important notes about Lemi B423E files
- 1024 bytes of ASCII metadata in the data file with scaling information
- Lemi B423E raw measurement data is signed long integer format
Important points about scalings
- Raw data is integer counts for electric channels
- Scalings in B423E files convert electric channels to uV (microvolt)
If apply_scaling is False, data will be returned in:
- microvolts for the electric channels
Which is equivalent to applying the scalings in the B423E headers
With apply_scaling True, the following additional scaling will be applied:
- Electric channels converted to mV
- Dipole length corrections are applied to electric channels
.. note::
For more information about Lemi B423 format, please see:
http://lemisensors.com/?p=485
"""
record_bytes: int = B423E_RECORD_BYTES
limit_chans: Optional[List[str]] = None
[docs] def read_data(
self, dir_path: Path, metadata: TimeMetadata, read_from: int, read_to: int
) -> TimeData:
"""
Get data from data files
Lemi B423E data always has four channels, in order E1, E2, E3, E4. When
writing out the metadata, it is possible to relabel these channels, for
example:
- Ex, Ey, E3, E4
The raw data is integer counts. However, additional scalings from the
B423 files are applied to give:
- microvolts for the electric channels
- millivolts for the magnetic with the gain applied
The scalings are as follows:
- Channel 1 = (Channel 1 * Ke1) + Ae1
- Channel 2 = (Channel 1 * Ke2) + Ae2
- Channel 3 = (Channel 1 * Ke3) + Ae3
- Channel 4 = (Channel 1 * Ke4) + Ae4
Unlike most other readers, the channels returned can be explicity
selected by setting the limit_chans attribute of the class. This is
because in many cases, only two of the B423Echannels are actually
useful.
Parameters
----------
dir_path : path
The directory path to read from
metadata : TimeMetadata
Time series data metadata
read_from : int
Sample to read data from
read_to : int
Sample to read data to
Returns
-------
TimeData
Time data object
"""
from resistics_readers.multifile import samples_to_sources
dtype = np.float32
n_samples = read_to - read_from + 1
chans, chan_indices = self._get_chans(dir_path, metadata)
n_chans = len(chans)
logger.info(f"Reading channels {chans}, indices {chan_indices}")
messages = [f"Reading raw data from {dir_path}"]
messages.append(f"Sampling rate {metadata.fs} Hz")
# loop over B423 files and read data
data_table = pd.DataFrame(data=metadata.data_table)
df_to_read = samples_to_sources(dir_path, data_table, read_from, read_to)
data = np.empty(shape=(n_chans, n_samples), dtype=dtype)
sample = 0
for data_file, info in df_to_read.iterrows():
file_from = info.loc["read_from"]
file_to = info.loc["read_to"]
n_samples_file = info.loc["n_samples_read"]
data_byte_start = info.loc["data_byte_start"]
mult = np.array([info.loc[B423E_MULT[idx]] for idx in chan_indices])
add = np.array([info.loc[B423E_ADD[idx]] for idx in chan_indices])
messages.append(f"{data_file}: Reading samples {file_from} to {file_to}")
logger.debug(f"{data_file}: Reading samples {file_from} to {file_to}")
byte_read_start = data_byte_start + file_from * self.record_bytes
n_bytes_to_read = n_samples_file * self.record_bytes
with (dir_path / data_file).open("rb") as f:
f.seek(byte_read_start, 0)
data_bytes = f.read(n_bytes_to_read)
data_read = self._parse_records(metadata.chans, data_bytes)
data_read = (data_read[chan_indices] * mult[:, None]) + add[:, None]
data[:, sample : sample + n_samples_file] = data_read
sample = sample + n_samples_file
metadata = self._adjust_metadata_chans(metadata, chans)
metadata = self._get_return_metadata(metadata, read_from, read_to)
messages.append(f"From sample, time: {read_from}, {str(metadata.first_time)}")
messages.append(f"To sample, time: {read_to}, {str(metadata.last_time)}")
metadata.history.add_record(self._get_record(messages))
logger.info(f"Data successfully read from {dir_path}")
return TimeData(metadata, data)
def _get_chans(
self, dir_path: Path, metadata: TimeMetadataMerge
) -> Tuple[List[str], List[int]]:
"""
Get the channels to read and their indices
This is mainly used because it is likely that not all the channels are
used or recording anything worthwhile
Parameters
----------
dir_path : Path
The directory path
metadata : TimeMetadataMerge
The metadata for the recording
Returns
-------
Tuple[List[str], List[int]]
The channels and the channel indices
Raises
------
TimeDataReadError
If any of limit_chans are not in the metadata.chans
"""
from resistics.errors import TimeDataReadError
if self.limit_chans is None:
return metadata.chans, list(range(metadata.n_chans))
chk = set(self.limit_chans) - set(metadata.chans)
if len(chk) > 0:
raise TimeDataReadError(
dir_path, f"Chans {chk} not in metadata {metadata.chans}"
)
indices = [metadata.chans.index(x) for x in self.limit_chans]
return self.limit_chans, indices
def _adjust_metadata_chans(
self, metadata: TimeMetadataMerge, chans: List[str]
) -> TimeMetadataMerge:
"""Adjust the channels in the metadata"""
metadata.chans_metadata = {c: metadata.chans_metadata[c] for c in chans}
metadata.chans = chans
metadata.n_chans = len(chans)
return metadata
[docs] def scale_data(self, time_data: TimeData) -> TimeData:
"""
Get data scaled to physical values
resistics uses field units, meaning physical samples will return the
following:
- Electrical channels in mV/km
- Magnetic channels in mV
- To get magnetic fields in nT, calibration needs to be performed
Notes
-----
When Lemi data is read in, scaling in the headers is applied. Therefore,
the magnetic channels is in mV with gain applied and the electric
channels are in uV (microvolts). To complete the scaling to field units,
the below additional corrections need to be applied.
Electric channels need to divided by 1000 along with dipole length
division in km (east-west spacing and north-south spacing) to return
mV/km.
Magnetic channels need to be divided by the internal gain value which
should be set in the metadata
Parameters
----------
time_data : TimeData
Input time data
Returns
-------
TimeData
Time data in field units
"""
logger.info("Applying scaling to data to give field units")
messages = ["Scaling raw data to physical units"]
for chan in time_data.metadata.chans:
chan_metadata = time_data.metadata.chans_metadata[chan]
time_data[chan] = time_data[chan] / 1000.0
messages.append(f"Dividing chan {chan} by 1000 to convert from uV to mV")
dipole_dist_km = chan_metadata.dipole_dist / 1_000
time_data[chan] = time_data[chan] / dipole_dist_km
messages.append(f"Dividing {chan} by dipole length {dipole_dist_km} km")
record = self._get_record(messages)
time_data.metadata.history.add_record(record)
return time_data